Vötsch VCE 1000 Test Chamber

VOC Test Chambers

The Vötsch VOC Test Chambers have been designed by industry specialists to measure the level of indoor emissions caused by Volatile Organic Compounds (VOCs). Two test chambers are available with capacities of 200 and 1000 litre.

The chambers have numerous fields of application including testing of consumer products and materials, passenger cars, electronic equipment, varnish, dyes, modern utility items and all types of clothing.

Options for the two standard models and further product customisations are also available dependent upon user requirements.

Product Features

  • Temperature range for climatic and temperature tests from +20°C to +130°C
  • Humidity range from 5%RH to 95%RH
  • Desorption up to +240°C
  • Choice of capacities - 200 and 1000 litre
  • 8" colour touch panel
  • S!MPAC/32-bit control and monitoring system with online service to Internet or mobile phone
  • USB and Ethernet interfaces
  • Digital I/O - four inputs and four outputs
  • Air-jacket temperature conditioning
  • Carrier gas climate conditioning
  • Fan with special drive mechanism
  • Mass flow controller
  • Absolute pressure measuring unit
  • Entry port septum
  • Air-cooled refrigeration unit
  • External located climatic module
  • Aerosol-free humidification and dehumidification
  • Emission-free humidification water tank in stainless steel
  • Automatic water replenishment
  • Low water alarm
  • Safety device for test specimens with independent temperature limiters tmin/tmax
  • Calibration of two temperature and two climate values
  • Test space chamber, electro-polished and pressure-proof to ±10mbar
  • Manufactured in Germany

Images

Related products

Technical Data

Vötsch Model

VCE 200

VCE 1000 Classic

Test space volume

208 litre

916 litre

Carrier gas

Purified compressed air, on-site

Purified compressed air, on-site

Performance range for temperature testing:

 

 

Conditioning

Air jacket

Air jacket

Temperature range

+20°C to +130°C

+20°C to +130°C

Performance range for climatic testing:

 

 

Conditioning

Carrier gas conditioning with climatic
module and evaporation system

Carrier gas conditioning with climatic
module and evaporation system

Temperature range

+20°C to +130°C

+20°C to +130°C

Humidity range

5%RH to 95%RH

5%RH to 95%RH

Performance range for desorption:

 

 

Temperature of desorption

Up to maximum +240°C, adjustable

Up to maximum +240°C, adjustable

Test space surface temperature

+220°C to +240°C

+220°C to +240°C

Interior test space dimensions (w x d x h)

610mm x 610mm x 560mm

750mm x 1630mm x 750mm

Exterior dimensions (w x d x h)

1250mm x 1700mm x 2350mm

1350mm x 2950mm x 2050mm

Supply voltage

3/N/PE AC 400V ±10% 50Hz

3/N/PE AC 400V ±10% 50Hz

Options

  • S!MPATI programming and logging software
  • Adjustable quantity of circulating air
  • Additional temperature and humidity measurement
  • Ozone, dust and particulate measurement
  • Increased ROC
  • Package for automotive testing

Additional options are also available upon request to suit specific user requirements.

^